Call or Text 877-804-3066     605 County Club Drive, Bensenville, IL 60106

Spring Cage Terminal Blocks Fuse Holders & Circuit Breakers12 Position Barrier Terminal Block - 14-22 AWG | Super Bright LEDs

Terminal Blocks for Factory or Field Wiring.  How to know what you’re getting –

 

Terminal Blocks come in many different forms.  They’re rated for difference wire sizes, voltages and ampacities, temperatures, short circuit ratings, and more.

 

Many don’t know, however, UL also rates them for Factory or Field wiring.  Terminal Blocks rated for Factory wiring only, cannot be used for wires to be installed in the field.  So, if you’re at UL with your product that has a Terminal Block intended to be wired in the field, you better make sure you pick the right one.

 

Picking the right one –

 

UL designates Terminal Blocks for Factory or Field Wiring.  See below from UL’s Guide Card on Terminal Blocks -

 

XCFR2.GuideInfo - Terminal Blocks - Component

 

Factory and/or Field Wiring (FW) — These terminal blocks are rated for: Code 1, factory wiring only, or Code 2, both factory and field wiring. The suitability of the connections (including spacings between factory connectors) shall be determined in the end-use application.

Unless noted with a "CA 4" in the last column, a terminal connector suitable for field wiring has been investigated to ANSI/UL 486A-486B, "Wire Connectors."

When Code 1 and Code 2 terminals are intermixed on the same terminal block, both codes will be used with suitable indication for which terminal each code applies, i.e., 1/2.

 

 

 

When looking for the right Terminal Block, look in the FW column on the companies UL Recognition card.

 

 

 

Series
No.

Wire
Range

Wire
Type


FW

TQ
In.-Lb


V


A


UG


CA

+FP

14

Cu

1

300

20

C

2(130),#

+FS

14

Cu

1

300

20

C

2(130),#

@FP-XX-25A

12

Cu

1

300

25

C

2(130),#

@FS-XX-25A

12

Cu

1

300

25

C

2(130),#

+D exept for D-11

4-18 SOL/STR

Cu

2

20

250/300

85

B/C

2(130),#

 

(2) 12-16 STR

Cu

2

20

250/300

35

B/C

2(130),#

 

(2) 18 SOL/STR

Cu

2

20

250/300

     
 

 

UL Furniture Safety Standards

By Ken Lui – PSC Project Engineer

If you are unsure about which furniture safety standard applies to your product, we can help with evaluation and managing your certification with UL.

 

  • UL 1286 Standards for Office Furnishings Safety Testing / Certification
  • UL 962 Standard for Safety Household and Commercial Furnishings Safety Testing Certification
  • UL 962A Furniture Power Distribution Units
  • UL 60601 Medical Safety Testing and Certification Services
  • UL 1678 Household, Commercial, and Professional-Use Carts and Stands for use with Audio/Video Equipment
  • UL 2040 Folding Rollaway Tables
  • UL 4041 Outline of Investigation for Outdoor Furniture

 

Product Safety Consulting has the expertise to help you navigate your product through UL certification as well as the laboratory capacity to analyze and stress test your product.

 

Product Safety Consulting has provided expert advice since 1988 and we have proficient working knowledge of global safety certification.

 

Contact us Today!

info@productsafetyinc.com

(630) 238-0188

Having Trouble getting your project across the Finish Line at your  NRTL?

We are here to help you!

Client A had been working with a NRTL for 15 months. Staff from the USA and Europe had also visited them at their facility multiple times only to be sent construction letter after construction letter. Once they heard from the engineer that the project was in for final review but nope, only to be sent another construction review letter outlining brand new items that would not be accepted.

With the frustration mounting, they Google “Help with NRTL” and found Product Safety Consulting Inc.!

We reviewed the latest two construction letters, went online and ordered a Certified Wiring Harness and various components, contacted the NRTL and presented the changes and reached agreement, flew to Europe and updated the construction, help modify the NRTL draft report, submitted the revised report, photos and illustrations to NRTL and 7 days later we were scheduling the IPI inspection for this brand new client for this NRTL. Total work time was 15 business days.

Give us a Jingle and let us see if we can help you start, continue or better yet Finish that NRTL project!